KCN Products Co.


Merchant Services

Join our mailing list!



(Your shopping cart is empty)

  Home > By Manufactuers > Altronix >

  Altronix AL1012ULACMCB Access power controller
  Altronix AL1012ULACMCB Access power controller
Altronix AL1012ULACMCB Access power controller
 
List Price: $558.00
Our Price: $372.00
You Save $186.00!

Manufacturer: Altronix

Product Code: KCN6-AL1012ULACMCB

Description
 
Overview
Model AL1012ULACMCB converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC Class 2 Rated power limited PTC protected Fail-Safe and/or Fail-Secure outputs with a total of 10 amp continuous supply current. The fire alarm disconnect feature enables emergency egress in the event the fire alarm system is activated. It is individually selectable for any or all of the eight (8) outputs. Model AL1012ULACM is a fuse protected version of this unit.
 
Features
Features/Specifications
Power Supply/Charger:
• 12VDC output.
• 10 amp of continuous supply current.
• Class 2 Rated power limited output.
• 115VAC 60Hz, 1.9 amp input.
• Filtered and electronically regulated outputs.
• Short circuit and thermal overload protection.
• Built-in charger for sealed lead acid or gel type battery backup.
• Maximum charge current .7 amp.
• Zero voltage drop upon transfer to battery backup.
• AC input and DC output LED indicators.
• AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
• Low battery and battery presence supervision (form "C" contact
rated @ 1 amp 28VDC).
Lifetime Warranty.

Access Power Controller:
• Eight (8) Access Control System outputs.
- Eight (8) PTC protected Fail-Safe and/or Fail-Secure 12VDC or 24VDC power outputs.
- Any power output may be converted to dry form "C" relay output.
- Eight (8) PTC protected 12VDC auxiliary power outputs (unswitched).
• Red LEDs indicate outputs are triggered (relays energized).
• Eight (8) Access Control System trigger inputs.
- Eight (8) normally open (NO) inputs.
- Eight (8) open collector inputs.
- Any combination of the above.
• Fire Alarm Disconnect:
- Fire Alarm Disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
- Normally open (NO) or normally closed (NC) dry contact input.
- Polarity reversal input FACP signaling circuit.
• Fire Alarm trigger LED indicates that the Fire Alarm Disconnect has been activated.
• Fire Alarm output relay for triggering auxiliary reporting devices (form "C" contact rated @ 1 amp 28VDC).
Lifetime Warranty.

Enclosure
• Accommodates up to two (2) 12VDC/12AH batteries.
• Dimensions: 15.5”H x 12”W x 4.5”D.
• 1/2" and 3/4" combination knockouts.

Related Products...
Altronix AL1012ULACMJ
Our Price: $390.67
Add
Altronix AL1012ULACMJ Same features as AL1012ULACM in larger enclosure 18
Altronix RDC12
Our Price: $17.33
Add
Altronix RDC12 UL Recognized relay and base - 12VDC operation 10 amp/120VAC/28VDC or 10 amp/277VAC DPDT contacts. 80mA current draw.
Altronix FUSE2
Our Price: $37.33
Add
Altronix FUSE2 5 amp glass fuse. Used in CCTV power supplies. Package of 100
Altronix AL600ULACM
Our Price: $350.67
Add
Altronix AL600ULACM Access power controller
Altronix RAC24
Our Price: $17.33
Add
Altronix RAC24 UL Recognized relay and base - 24VAC operation 10 amp/120VAC/28VDC or 10 amp/277VAC DPDT contacts. 50mA current draw.


 Share your knowledge of this product with other customers... Be the first to write a review.



Browse for more products in the same category as this item:

By Manufactuers > Altronix
By Manufactuers > Altronix > Altronix ACM SERIES - 8 OUTPUT ACCESS POWER CONTROLLERS (PTC PROTECTED OUTPUTS)
By Manufactuers
KCN Products
53-55 East Jackson Street
Wilkes-Barre, PA 18701
 About Us
 Become an Affiliate
 Privacy Policy
 Send Us Feedback
 
Company Info | Advertising | Product Index | Category Index | Help | Terms of Use
Copyright © 2004 KCN Products Co.. All Rights Reserved.
eCommerce Powered by Volusion.